This page details digital I/O timing specifications for the OV20i, including trigger signal timing, output latency, and recommended pulse widths.
Digital Input Timing
Trigger Input Timing (Pin 16)
Parameter | Spec |
---|---|
Input Activation Type | NPN (Pull to GND) |
Minimum Pulse Width | 10 ms |
Input Debounce | ~5 ms |
Max Input Frequency | ~20 Hz |
Signal Type | Dry contact or open collector |
Trigger fires once per pulse
Ideal for sensors with clean output transitions
Digital Output Timing
Result Output Timing (Pins 10 & 11)
Event | Timing |
---|---|
Output Activation Delay | ~10–15 ms after inference |
Output Active Duration | Configurable (default 100 ms) |
Max Current | 100 mA |
Output Logic Type | NPN open collector (pulls to GND) |
note
External pull-up to 24 VDC is required for most PLCs.
Typical Timing Sequence (Digital Trigger)
CopyEdit
Trigger Pulse
___
| |____________________
|
|<-- 10 ms -->|
Inference Timing (AI Process)
_______________________
/
Result Output __/
|<-- ~10–15 ms after trigger -->|
Recommended Setup
- Trigger via dry contact, NPN sensor, or PLC sinking output
- Set minimum pulse width: 10–20 ms
- Configure output duration via UI or PLC tag if required
Best Practices
- Use shielded cables to minimize noise
- Confirm rising/falling edge behavior matches PLC expectations
- Check output with a test light or multimeter during setup
- Avoid signal bounce by using sensors with built-in debounce